Product Center


平度Vertical surface-mounted fan coil unit

Water‑system air‑conditioning terminal heat‑exchange units, wall‑mounted and floor‑standing with exposed installation; the unit includes a switch. Standard operating conditions: cooling—7°C chilled water; heating—60°C low‑temperature hot water. During summer cooling, condensate drainage must be addressed; a thermostat can be optionally installed for temperature control.

Category:

平度Fan coil unit

Phone: 024-89722880

Product Description

Model Name
FP-LM Vertical Surface-Mounted Fan Coil Unit

Main uses
Heat exchange and air supply at the terminal units of the water-based air-conditioning system.

Place of Use
Surface-mounted, floor-to-ceiling.

Product Overview
Water‑system air‑conditioning terminal heat‑exchanger units, wall‑mounted and floor‑standing with exposed installation; the unit includes a switch.
These are the standard operating conditions: cooling—7°C chilled water; heating—60°C low‑temperature hot water.
In summer cooling applications, condensate drainage must be considered; a thermostat can be optionally installed for temperature control.

Main Parameters

Model number Length × Width × Height mm Heating capacity kW Cooling capacity kW Inlet and outlet pipe diameter Input power W (220V) Airflow m 3/h
FP-34LM 770*230*620 3.39 1.98 DN20 37 340
FP-51LM 920*230*620 4.5 2.8 DN20 52 510
FP-68LM 990*230*620 6.35 3.87 DN20 62 680
FP-85LM 1140*230*620 7.45 4.58 DN20 76 850
FP-102LM 1220*230*620 9.22 5.42 DN20 96 1020
FP-136LM 1430*230*620 12.4 7.38 DN20 134 1360
FP-170LM 1650*230*620 16.3 9.08 DN20 152 1700
FP-204LM 1870*230*620 19.5 11.1 DN20 189 2040
FP-238LM 2020*230*620 20.2 12.9 DN20 228 2380

Note:
1. Cooling capacity operating conditions: inlet air dry-bulb temperature 27°C, wet-bulb temperature 19.5°C, chilled water inlet temperature 7°C, and a water temperature difference of 5°C.
2. Heating‑mode operating parameters: inlet air dry‑bulb temperature 21°C, inlet water temperature 60°C, and hot‑water flow rate identical to that in the cooling mode.
3. Input power operating condition parameters: working pressure 12 Pa.

Precautions
It is recommended to increase the selection of equipment and ensure adequate freeze‑protection measures during winter.

 

 