Product Center


蒙自Enhance the axial-flow, side-blowing hot-water-steam air curtain.

Compact model with a small cross-section, low noise level, and weak blocking performance; suitable for narrow openings. Designed for bilateral airflow, it is installed on both sides of the opening and operated with opposing airflows; the unit includes an on/off switch. Customizable machine height to match door height; the unit must be securely anchored to the floor and side walls before use. The housing is made of carbon steel with a white electrostatic powder coating; custom housing colors or stainless steel panels are available. The hot‑water version requires water at 70°C or higher, while the steam version requires steam at 0.4 MPa or less. Operating ambient temperatures must be above 5°C; during the heating season, continuous heat supply is required to prevent freezing and cracking of the internal heat exchanger.

Category:

蒙自Side-blowing hot steam air curtain

Phone: 024-89722880

Product Description

Model Name   
RM19Z-C-S(Q) Side-Blow Series I

Main uses     
For narrow openings no wider than 3 meters, install on both sides to prevent outdoor air from entering and to provide indoor heat supplementation.

Place of Use  
For narrow openings where blocking performance is not critical and top-blowing units cannot be installed, supplemental heating is the primary approach.

Product Overview     
Small-sized models feature compact cross-sectional dimensions, low noise levels, and limited blocking performance, making them suitable for narrow openings.
Designed for bilateral blowing, it is installed on both sides of the opening and operates with opposing airflow; the unit is equipped with an on/off switch.
Customize the machine height to match the door height; the machine must be securely anchored to the floor and side walls before use.
The enclosure is made of carbon steel with a white electrostatic powder coating; custom enclosure colors or stainless steel panels are available.
The hot-water type requires water at a temperature of 70°C or higher, while the steam type requires steam at a pressure of 0.4 MPa or lower.
The ambient temperature must be maintained above 5°C, and continuous heating is required during the heating season to prevent freezing and cracking of the internal heat exchanger.

Main Parameters  
Hot-water type

Model number Height
mm
Motor total
Power W (220V)
Air volume
m 3/h
Wind speed
m/s
Enter and exit
Pipe diameter
Supply and return water temperatures: 70/60°C Supply and return water temperatures: 80/65°C Supply and return water temperatures: 90/70°C
Heating capacity
kilowatt
Heating capacity
kilowatt
Heating capacity
kilowatt
RM1920Z-C-S 2000 595 3500 8 DN32 28 35 42
RM1923Z-C-S 2300 680 4000 32 41 49
RM1925Z-C-S 2500 765 4500 36 45 54


Steam-type

Model number Height
mm
Motor total
Power W (220V)
Air volume
m 3/h
Wind speed
m/s
Enter and exit
Pipe diameter
Steam pressure 0.1 MPa Steam pressure 0.2 MPa Steam pressure 0.3 MPa
Heating capacity
kilowatt
Heating capacity
kilowatt
Heating capacity
kilowatt
RM1920Z-C-Q 2000 595 3500 8 DN25 35 46 53
RM1923Z-C-Q 2300 680 4000 41 54 62
RM1925Z-C-Q 2500 765 4500 45 59 68


Precautions     
1. Custom-made to the door’s height.
2. If high blocking performance is required, this model is not recommended.

 

 

 