Vertical surface-mounted fan coil unit

Water‑system air‑conditioning terminal heat‑exchange units, wall‑mounted and floor‑standing with exposed installation; the unit includes a switch. Standard operating conditions: cooling—7°C chilled water; heating—60°C low‑temperature hot water. During summer cooling, condensate drainage must be addressed; a thermostat can be optionally installed for temperature control.

Keywords:

Category:

Sales hotline:

  • Description
  • Model Name
    FP-LM Vertical Surface-Mounted Fan Coil Unit

    Main uses
    Heat exchange and air supply at the terminal units of the water-based air-conditioning system.

    Place of Use
    Surface-mounted, floor-to-ceiling.

    Product Overview
    Water‑system air‑conditioning terminal heat‑exchanger units, wall‑mounted and floor‑standing with exposed installation; the unit includes a switch.
    These are the standard operating conditions: cooling—7°C chilled water; heating—60°C low‑temperature hot water.
    In summer cooling applications, condensate drainage must be considered; a thermostat can be optionally installed for temperature control.

    Main Parameters

    Model number Length × Width × Height mm Heating capacity kW Cooling capacity kW Inlet and outlet pipe diameter Input power W (220V) Airflow m 3/h
    FP-34LM 770*230*620 3.39 1.98 DN20 37 340
    FP-51LM 920*230*620 4.5 2.8 DN20 52 510
    FP-68LM 990*230*620 6.35 3.87 DN20 62 680
    FP-85LM 1140*230*620 7.45 4.58 DN20 76 850
    FP-102LM 1220*230*620 9.22 5.42 DN20 96 1020
    FP-136LM 1430*230*620 12.4 7.38 DN20 134 1360
    FP-170LM 1650*230*620 16.3 9.08 DN20 152 1700
    FP-204LM 1870*230*620 19.5 11.1 DN20 189 2040
    FP-238LM 2020*230*620 20.2 12.9 DN20 228 2380

    Note:
    1. Cooling capacity operating conditions: inlet air dry-bulb temperature 27°C, wet-bulb temperature 19.5°C, chilled water inlet temperature 7°C, and a water temperature difference of 5°C.
    2. Heating‑mode operating parameters: inlet air dry‑bulb temperature 21°C, inlet water temperature 60°C, and hot‑water flow rate identical to that in the cooling mode.
    3. Input power operating condition parameters: working pressure 12 Pa.

    Precautions
    It is recommended to increase the selection of equipment and ensure adequate freeze‑protection measures during winter.

     

     