Large-space hot water heating fan
Keywords:
Category:
- Description
-
Model Name
NF-S(Q)ZBH High-Space Hanging Series
Main Use
Intermittent heating product for hanging in high-space buildings with a ceiling height of more than 6 meters.
Place of Use
Workshops, warehouses, exhibition halls, and various venues with high ceilings and large areas.
Product Introduction
Air is delivered from the bottom of the machine, which can reduce the temperature difference in the height direction and significantly improve energy efficiency;
The outlet is equipped with a swirl air outlet to increase the air diffusion angle and improve the coverage area;
Small models are suitable for low ceiling heights or small areas, with lower noise and better comfort;
Large models are suitable for high ceiling heights or large areas, with long air delivery distance and large coverage area;
Requires external control box, with wired and wireless control options;
A supporting product for HVAC engineering, customizable according to construction drawings or tender requirements.
Main Parameters
Hot Water TypeModel Length*Width*Height mm Motor Power W(380V) Air Volume m³ 3/h Inlet and Outlet Pipe Diameter Inlet/Outlet Water 60/50℃ Inlet/Outlet Water 70/60℃ Inlet/Outlet Water 80/65℃ Heating Capacity kW Heating Capacity kW Heating Capacity kW NF-S50ZBH 800*800*800 500 5000 DN40 38 45 51 NF-S60ZBH 880*880*810 550 6000 DN40 45 54 61 NF-S80ZBH 1000*1000*810 850 8000 DN50 60 72 81 NF-S100ZBH 1080*1080*850 1100 10000 DN50 75 90 101
Steam TypeModel Length * Width * Height mm Motor Power W(380V) Air Volume m³ 3/h Inlet and Outlet Pipe Diameter Steam Pressure 0.1MPa Steam Pressure 0.2MPa Steam Pressure 0.3MPa Heating Capacity kW Heating Capacity kW Heating Capacity kW NF-Q50ZBH 800*800*800 500 5000 DN32 45 60 69 NF-Q60ZBH 850*850*810 550 6000 DN32 54 72 82 NF-Q80ZBH 980*980*810 850 8000 DN40 73 96 111 NF-Q100ZBH 1050*1050*850 1100 10000 DN40 90 119 136
Precautions
1. Only suitable for large venues. Select the model and quantity according to the size and noise requirements of the venue.
2. Press down the high-temperature air accumulated at high altitudes to reduce the temperature difference in the height direction and achieve energy saving and consumption reduction.
3. For a small number of centrally controlled machines, it is recommended to use wired control.