Axial side-blown hot steam air curtain
Keywords:
Category:
- Description
-
Model Name
RM35(45、63)Z-C-S(Q) Side-blowing Series II
Main Use
Installation on both sides of large openings 3-6 meters wide to block outdoor air and provide indoor heating.
Place of Use
Vehicle entrances and exits of factories and warehouses, main entrances of large commercial buildings, and garage ramps.
Product Introduction
Large unit, large air volume, large heating capacity, suitable for large openings or places requiring a large amount of supplementary heating. Designed for double-sided blowing. If the installation location is limited, single-sided blowing can be used, requiring an increase in machine size and customized machine height. The machine should be level with the door. The machine needs to be fixed to the ground and side walls before use. The casing is made of electrostatic spray-painted white carbon steel plate. Customized casing colors or stainless steel panels are available. Ambient temperature above 5℃ is required. Continuous heating is required during the heating season to prevent internal heat exchanger from freezing. Hot water type requires water above 70℃, steam type requires steam below 0.4MPa. Available with or without zone control; the latter requires an additional control box to operate the machine.
Classification by Fan Model:
RM35Z-C-S(Q): Low noise, suitable for narrow openings and quiet commercial environments.
RM45Z-C-S(Q): Suitable for main entrances of commercial buildings, vehicle entrances and exits of factories and warehouses.
RM63Z-C-S(Q): Large heating capacity, suitable for large openings or places requiring a large amount of supplementary heating.
Classification by Heating Range:
Energy-saving type: Hot air heating below 2 meters in height, natural wind sealing above 2 meters.
Standard type: Hot air blowing at the entire height, large heating capacity, suitable for places requiring a large amount of supplementary heating.
Main Parameters
Hot Water TypeOpening
Width
mModel Machine Height
mmTotal Motor Power
W(380V)Air Volume
m 3/hAir Speed
m/sIn/Out
Pipe DiameterNoise
dB(A)Weight
kgInlet/Outlet Water 70/60℃ Inlet/Outlet Water 80/65℃ Inlet/Outlet Water 90/70℃ Heating Capacity
kWTemperature Rise
℃Heating Capacity
kWTemperature Rise
℃Heating Capacity
kWTemperature Rise
℃3-3.6 RM3522Z-C-S 2200 680 6400 8 DN40 62 270 53 24 66 31 80 37 RM3530Z-C-S 3000 1020 9600 64 370 76 23 96 30 116 36 RM3536Z-C-S 3600 1190 11200 65 450 88 23 111 30 134 35 RM3540Z-C-S 4000 1360 12800 66 500 100 23 126 29 152 35 3-4.2 RM4522Z-C-S 2200 750 10500 10 DN50 64 310 72 20 90 25 109 31 RM4528Z-C-S 2800 1000 14000 65 390 96 20 120 25 145 31 RM4534Z-C-S 3400 1250 17500 66 480 112 19 140 24 170 29 RM4540Z-C-S 4000 1500 21000 67 570 136 19 170 24 206 29 RM4546Z-C-S 4600 1750 24500 68 660 160 19 200 24 242 29 RM4552Z-C-S 5200 2000 28000 69 750 184 19 230 24 279 29 4-6 RM6320Z-C-S 2000 1100 10800 12 DN65 68 370 80 22 101 27 122 33 RM6328Z-C-S 2800 1650 16200 69 520 121 22 151 27 183 33 RM6336Z-C-S 3600 2200 21600 70 670 151 21 189 26 229 32 RM6344Z-C-S 4400 2750 27000 71 820 191 21 240 26 290 32 RM6352Z-C-S 5200 3300 32400 72 970 232 21 290 26 352 32 RM6360Z-C-S 6000 3850 37800 73 1120 272 21 341 26 413 32
Steam TypeOpening
Width
mModel Machine Height
mmTotal Motor Power
W(380V)Air Volume
m 3/hAir Speed
m/sIn/Out
Pipe DiameterNoise
dB(A)Weight
kgSteam Pressure 0.1MPa Steam Pressure 0.2MPa Steam Pressure 0.3MPa Heating Capacity
kWTemperature Rise
℃Heating Capacity
kWTemperature Rise
℃Heating Capacity
kWTemperature Rise
℃3-3.6 RM3522Z-C-Q 2200 680 6400 8 DN32 62 245 68 31 90 41 103 48 RM3530Z-C-Q 3000 1020 9600 64 330 98 30 130 40 149 46 RM3536Z-C-Q 3600 1190 11200 65 365 114 30 150 39 172 45 RM3540Z-C-Q 4000 1360 12800 66 445 129 30 170 39 195 45 3-4.2 RM4522Z-C-Q 2200 750 10500 10 DN40 64 280 95 27 126 35 144 41 RM4528Z-C-Q 2800 1000 14000 65 350 127 27 168 35 193 41 RM4534Z-C-Q 3400 1250 17500 66 425 148 25 196 33 225 38 RM4540Z-C-Q 4000 1500 21000 67 505 180 26 238 34 273 39 RM4546Z-C-Q 4600 1750 24500 68 585 212 26 280 34 322 39 RM4552Z-C-Q 5200 2000 28000 69 660 244 26 322 34 370 39 4-6 RM6320Z-C-Q 2000 1100 10800 12 DN50 68 335 107 29 140 38 161 44 RM6328Z-C-Q 2800 1650 16200 69 465 160 29 211 38 242 44 RM6336Z-C-Q 3600 2200 21600 70 595 200 28 264 36 303 42 RM6344Z-C-Q 4400 2750 27000 71 725 254 28 334 37 384 43 RM6352Z-C-Q 5200 3300 32400 72 860 307 28 404 37 465 43 RM6360Z-C-Q 6000 3850 37800 73 990 361 28 475 37 546 43 Remarks:
1. Parameters are calculated based on an inlet air temperature of 5℃; "Temperature Rise" refers to the temperature increase of the air heated by the heat exchanger.
2. These are standard parameters; the "Heating Capacity" of the energy-saving type is the heating capacity of the 2 or 2.2-meter-high machine of the same series in the table. Other parameters of the energy-saving type can refer to the standard type.
Precautions
1. Customizable parameters, machine height, and control functions.
2. If high blocking effect is required, this model is not recommended.