undefined
undefined
+
  • undefined
  • undefined

Axial side-blown hot steam air curtain

Large model, large air volume, large heating capacity, suitable for wide openings or places requiring a large amount of supplementary heating. Designed for double-sided blowing. If the installation location is limited, single-sided blowing can be used, requiring an increase in machine model and customized machine height to be flush with the door. The machine needs to be fixed to the ground and side walls before use. The casing is made of carbon steel plate with electrostatic white spraying. Customized casing color or stainless steel panel is available. Requires an ambient temperature above 5℃. Continuous heating is required during the heating season to prevent internal heat exchanger from freezing. Water type requires water above 70℃, and steam type requires steam below 0.4MPa. Available in zoned control type and non-zoned control type. The latter requires additional control box for operation.

Keywords:

Sales hotline:

  • Description
  • Model Name   
    RM35(45、63)Z-C-S(Q) Side-blowing Series II

    Main Use     
    Installation on both sides of large openings 3-6 meters wide to block outdoor air and provide indoor heating.

    Place of Use  
    Vehicle entrances and exits of factories and warehouses, main entrances of large commercial buildings, and garage ramps.

    Product Introduction     
    Large unit, large air volume, large heating capacity, suitable for large openings or places requiring a large amount of supplementary heating. Designed for double-sided blowing. If the installation location is limited, single-sided blowing can be used, requiring an increase in machine size and customized machine height. The machine should be level with the door. The machine needs to be fixed to the ground and side walls before use. The casing is made of electrostatic spray-painted white carbon steel plate. Customized casing colors or stainless steel panels are available. Ambient temperature above 5℃ is required. Continuous heating is required during the heating season to prevent internal heat exchanger from freezing. Hot water type requires water above 70℃, steam type requires steam below 0.4MPa. Available with or without zone control; the latter requires an additional control box to operate the machine.
    Classification by Fan Model:
    RM35Z-C-S(Q): Low noise, suitable for narrow openings and quiet commercial environments.
    RM45Z-C-S(Q): Suitable for main entrances of commercial buildings, vehicle entrances and exits of factories and warehouses.
    RM63Z-C-S(Q): Large heating capacity, suitable for large openings or places requiring a large amount of supplementary heating.
    Classification by Heating Range:
    Energy-saving type: Hot air heating below 2 meters in height, natural wind sealing above 2 meters.
    Standard type: Hot air blowing at the entire height, large heating capacity, suitable for places requiring a large amount of supplementary heating.

    Main Parameters
    Hot Water Type

    Opening
    Width
    m
    Model Machine Height
    mm
    Total Motor Power
    W(380V)
    Air Volume
    m 3/h
    Air Speed
    m/s
    In/Out
    Pipe Diameter
    Noise
    dB(A)
    Weight
    kg
    Inlet/Outlet Water 70/60℃ Inlet/Outlet Water 80/65℃ Inlet/Outlet Water 90/70℃
    Heating Capacity
    kW
    Temperature Rise
    Heating Capacity
    kW
    Temperature Rise
    Heating Capacity
    kW
    Temperature Rise
    3-3.6 RM3522Z-C-S 2200 680 6400 8 DN40 62 270 53 24 66 31 80 37
    RM3530Z-C-S 3000 1020 9600 64 370 76 23 96 30 116 36
    RM3536Z-C-S 3600 1190 11200 65 450 88 23 111 30 134 35
    RM3540Z-C-S 4000 1360 12800 66 500 100 23 126 29 152 35
    3-4.2 RM4522Z-C-S 2200 750 10500 10 DN50 64 310 72 20 90 25 109 31
    RM4528Z-C-S 2800 1000 14000 65 390 96 20 120 25 145 31
    RM4534Z-C-S 3400 1250 17500 66 480 112 19 140 24 170 29
    RM4540Z-C-S 4000 1500 21000 67 570 136 19 170 24 206 29
    RM4546Z-C-S 4600 1750 24500 68 660 160 19 200 24 242 29
    RM4552Z-C-S 5200 2000 28000 69 750 184 19 230 24 279 29
    4-6 RM6320Z-C-S 2000 1100 10800 12 DN65 68 370 80 22 101 27 122 33
    RM6328Z-C-S 2800 1650 16200 69 520 121 22 151 27 183 33
    RM6336Z-C-S 3600 2200 21600 70 670 151 21 189 26 229 32
    RM6344Z-C-S 4400 2750 27000 71 820 191 21 240 26 290 32
    RM6352Z-C-S 5200 3300 32400 72 970 232 21 290 26 352 32
    RM6360Z-C-S 6000 3850 37800 73 1120 272 21 341 26 413 32


    Steam Type

    Opening
    Width
    m
    Model Machine Height
    mm
    Total Motor Power
    W(380V)
    Air Volume
    m 3/h
    Air Speed
    m/s
    In/Out
    Pipe Diameter
    Noise
    dB(A)
    Weight
    kg
    Steam Pressure 0.1MPa Steam Pressure 0.2MPa Steam Pressure 0.3MPa
    Heating Capacity
    kW
    Temperature Rise
    Heating Capacity
    kW
    Temperature Rise
    Heating Capacity
    kW
    Temperature Rise
    3-3.6 RM3522Z-C-Q 2200 680 6400 8 DN32 62 245 68 31 90 41 103 48
    RM3530Z-C-Q 3000 1020 9600 64 330 98 30 130 40 149 46
    RM3536Z-C-Q 3600 1190 11200 65 365 114 30 150 39 172 45
    RM3540Z-C-Q 4000 1360 12800 66 445 129 30 170 39 195 45
    3-4.2 RM4522Z-C-Q 2200 750 10500 10 DN40 64 280 95 27 126 35 144 41
    RM4528Z-C-Q 2800 1000 14000 65 350 127 27 168 35 193 41
    RM4534Z-C-Q 3400 1250 17500 66 425 148 25 196 33 225 38
    RM4540Z-C-Q 4000 1500 21000 67 505 180 26 238 34 273 39
    RM4546Z-C-Q 4600 1750 24500 68 585 212 26 280 34 322 39
    RM4552Z-C-Q 5200 2000 28000 69 660 244 26 322 34 370 39
    4-6 RM6320Z-C-Q 2000 1100 10800 12 DN50 68 335 107 29 140 38 161 44
    RM6328Z-C-Q 2800 1650 16200 69 465 160 29 211 38 242 44
    RM6336Z-C-Q 3600 2200 21600 70 595 200 28 264 36 303 42
    RM6344Z-C-Q 4400 2750 27000 71 725 254 28 334 37 384 43
    RM6352Z-C-Q 5200 3300 32400 72 860 307 28 404 37 465 43
    RM6360Z-C-Q 6000 3850 37800 73 990 361 28 475 37 546 43

    Remarks:
    1. Parameters are calculated based on an inlet air temperature of 5℃; "Temperature Rise" refers to the temperature increase of the air heated by the heat exchanger.
    2. These are standard parameters; the "Heating Capacity" of the energy-saving type is the heating capacity of the 2 or 2.2-meter-high machine of the same series in the table. Other parameters of the energy-saving type can refer to the standard type.

    Precautions
    1. Customizable parameters, machine height, and control functions.
    2. If high blocking effect is required, this model is not recommended.

     

     