Ceiling-mounted hot steam air curtain

Models for use with suspended ceilings, embedded installation, with only the machine panel exposed; The panel is large, capable of covering the gap between the casing and the suspended ceiling; maintenance can be done by removing the panel; The panel is made of carbon steel plate with electrostatic white powder coating, and custom panel colors or stainless steel material are available; Requires ambient temperature above 5℃; continuous heating is needed during heating season to prevent internal heat exchanger freeze cracking; Machine length does not include inlet/outlet pipes; pipe and pipe accessories' space must be considered during selection; Hot water models require hot water above 60℃; steam models require steam below 0.4MPa; Available in remote control type and non-control type; the non-control type is only for centralized control in engineering applications.

Keywords:

Sales hotline:

  • Description
  • Model Name   
    RM16 (20, 23) LQR-S(Q) Embedded Series

    Main Use     
    Embedded installation on suspended ceilings within 3.2 meters in height, blocking outdoor air entry and providing indoor heating supplementation.

    Places of Use  
    Locations requiring embedded installation of the unit on suspended ceilings.

    Product Introduction     
    A model designed for use with decorative suspended ceilings, featuring embedded installation with only the unit panel exposed outside the ceiling;
    Large panel size to conceal gaps between the unit and the ceiling; the panel can be removed for maintenance;
    The panel is made of electrostatic spray-painted white carbon steel, and custom panel colors or stainless steel material are available;
    Requires an ambient temperature above 5℃, continuous heating is required during the heating season to prevent internal heat exchanger cracking;
    The machine length does not include the inlet and outlet water pipes; the space occupied by the water pipes and pipe fittings should be considered when selecting a model;
    Hot water type requires hot water above 60℃, steam type requires steam below 0.4MPa;
    Available in remote control and non-control types; non-control types are only for centralized control in engineering applications.
    Classification by Fan Model:
    RM16LQR-S(Q): Low noise, suitable for small spaces with low ceilings and quiet environments;
    RM20LQR-S(Q): Balances noise and blocking effect, suitable for medium and large quiet spaces;
    RM23LQR-S(Q): Good blocking effect, suitable for large spaces with high ceilings and high traffic flow.
    Comparison with Recessed Models:
    Easy Installation: The panel size is larger than the unit, concealing gaps between the unit and the ceiling;
    Easy Maintenance: The panel can be removed for maintenance, and the unit can be removed without damaging the ceiling;
    High Efficiency and Energy Saving: It draws in hot air from under the ceiling as intake air, resulting in a higher outlet air temperature for the same heating capacity.

    Main Parameters
    Hot Water Type

    Installation
    Height
    m
    Model Power Supply
    V
    Panel Length
    mm
    Motor
    Total Power W
    Air Volume
    m 3/h
    Air Speed
    m/s
    Inlet/Outlet
    Pipe Diameter
    Inlet/Outlet Water 70/60℃ Inlet/Outlet Water 80/65℃ Inlet/Outlet Water 90/70℃
    Heating Capacity
    kW
    Heating Capacity
    kW
    Heating Capacity
    kW
    2.4-2.6 RM1609LQR-S 220 930 200 1700 9 DN32 15 20 24
    RM1612LQR-S 1230 300 2550 10 22 29 34
    RM1615LQR-S 1530 400 3400 10 28 37 44
    RM1618LQR-S 1830 400 3400 9 30 40 48
    RM1620LQR-S 2030 500 4250 10 39 52 60
    2.5-3 RM2009LQR-S 380 930 250 1600 8 DN40 17 23 27
    RM2012LQR-S 1230 440 2600 9 25 33 39
    RM2015LQR-S 1530 500 3200 9 32 43 50
    RM2018LQR-S 1830 500 3200 8 36 48 56
    RM2020LQR-S 2030 750 4800 9 45 60 70
    2.8-3.2 RM2309LQR-S 380 930 370 2000 9 DN50 20 26 31
    RM2312LQR-S 1230 640 3400 10 28 38 44
    RM2315LQR-S 1530 740 4000 10 37 49 58
    RM2318LQR-S 1830 740 4000 9 41 55 64
    RM2320LQR-S 2030 1110 6000 10 51 69 80


    Steam Type

    Installation
    Height
    m
    Model Power Supply
    V
    Panel Length
    mm
    Motor
    Total Power W
    Air Volume
    m 3/h
    Air Speed
    m/s
    Inlet/Outlet
    Pipe Diameter
    Steam Pressure 0.1MPa Steam Pressure 0.2MPa Steam Pressure 0.3MPa
    Heating Capacity
    kW
    Heating Capacity
    kW
    Heating Capacity
    kW
    2.4-2.6 RM1609LQR-Q 220 930 200 1700 9 DN25 17 22 25
    RM1612LQR-Q 1230 300 2550 10 23 31 35
    RM1615LQR-Q 1530 400 3400 10 30 39 45
    RM1618LQR-Q 1830 400 3400 9 34 44 50
    RM1620LQR-Q 2030 500 4250 10 40 53 61
    2.5-3 RM2009LQR-Q 380 930 250 1600 8 DN32 19 25 29
    RM2012LQR-Q 1230 440 2600 9 26 35 40
    RM2015LQR-Q 1530 500 3200 9 34 44 51
    RM2018LQR-Q 1830 500 3200 8 37 49 56
    RM2020LQR-Q 2030 750 4800 9 46 60 70
    2.8-3.2 RM2309LQR-Q 380 930 370 2000 9 DN40 24 32 36
    RM2312LQR-Q 1030 640 3400 10 33 44 50
    RM2315LQR-Q 1530 740 4000 10 42 56 64
    RM2318LQR-Q 1830 740 4000 9 46 61 70
    RM2320LQR-Q 2030 1110 6000 10 57 76 87


    Notes
    Engineering-配套 model, customizable according to drawing length and parameters.

     

     

Product inquiry

Contact us immediately for free expert consultation!

Submit
%{tishi_zhanwei}%
%E7%AC%AC%E4%B8%80%EF%BC%8C%E6%9C%80%EF%BC%8C%E4%BC%98%E7%A7%80%EF%BC%8C%E5%A2%9E%E5%BC%BA%EF%BC%8C%E4%B8%80%E6%B5%81%EF%BC%8C%E5%8D%93%E8%B6%8A%2F%2F%2F%E6%9D%B0%E5%87%BA%EF%BC%8C%E9%A2%86%E5%85%88%EF%BC%8C%E5%85%88%E8%BF%9B%EF%BC%8C%E5%BC%95%E9%A2%86

Sorry,当前栏目暂无内容!

您可以查看其他栏目或返回 首页

Sorry,The current column has no content!

You can view other columns or return Home