Industrial Hot Water Steam Air Curtain

Large model, large air volume, large heating capacity, suitable for large venues that require a large amount of heat supplementation; The machine comes with a hanger, and a bracket or hanging rod is separately provided to fix the machine to the side wall or hang it under the shed; The shell is made of carbon steel plate with electrostatic spraying in white, and the shell color or stainless steel panel can be customized; The ambient temperature is required to be above 5℃, and continuous heating is required during the heating season to prevent the internal heat exchanger from cracking; The length of the machine does not include the water inlet and outlet pipes. When selecting a model, the space occupied by the water pipes and pipe fittings should be considered; Hot water type requires the use of hot water above 60℃, and steam type requires the use of steam below 0.4MPa; The machine does not include the control part, and a separate switch box or control box is required to control the use of the machine.

Keywords:

Sales hotline:

  • Description
  • Model Name   
    RM35(45, 63)Z-S(Q) Engineering Series

    Main Purpose     
    Installed at a height of 3-5 meters, the lower the better, to block outdoor air from entering and provide indoor heat supplementation;
    Primarily for factory use, or in places where a large amount of heat supplementation is required to be used

    Application Scenarios  
    Motor vehicle entrances/exits of factory warehouses, main entrances of large venues, or underground parking garage ramps

    Product Introduction     
    Large model, large air volume, high heating capacity, suitable for large venues requiring significant heat supplementation;
    The machine comes with a hanging bracket, and additional brackets or hanging rods are needed to fix the machine to the side wall or hang it under the ceiling;
    The casing is made of carbon steel plate with electrostatic white powder coating; the casing can be customized in color or with a stainless steel panel;
    Requires ambient temperature above 5℃. Continuous heating is needed during the heating season to prevent the internal heat exchanger from freezing and cracking;
    The machine length does not include the inlet/outlet pipes. When selecting, consider the space occupied by pipes and pipe fittings;
    Hot water type requires hot water above 60℃, steam type requires steam below 0.4MPa;
    The machine does not include the control unit; a separate switch box or control cabinet is needed to control the machine's operation
    Classified by Fan Model:
    RM35Z-S(Q): Low noise, suitable for locations where the machine installation height is low and the environment is quiet;
    RM45Z-S(Q): Suitable for main entrances of large commercial venues, and vehicle entrances/exits of factory warehouses;
    RM63Z-S(Q): High heating capacity, suitable for high openings like factories or places requiring significant heat supplementation

    Product Images

    Main Parameters
    Hot Water Type

    Installation Height
    m
    Model L*W*H
    mm
    Total Motor Power
    W(380V)
    Air Volume
    m 3/h
    Air Speed
    m/s
    Inlet/Outlet
    Pipe Diameter
    Inlet/Return Water 70/60℃ Inlet/Return Water 80/65℃ Inlet/Return Water 90/70℃
    Heating Capacity
    kW
    Heating Capacity
    kW
    Heating Capacity
    kW
    ≤3.2 RM3505Z-S 500*500*630 170 1600 8 DN40 11 15 17
    RM3509Z-S 900*500*630 340 3200 25 34 40
    RM3514Z-S 1350*500*630 510 4800 42 56 65
    RM3518Z-S 1800*500*630 680 6400 58 77 90
    RM3523Z-S 2250*500*630 850 8000 74 99 115
    3-4 RM4506Z-S 600*650*690 250 3500 9 DN50 22 29 35
    RM4512Z-S 1200*650*690 500 7000 54 72 84
    RM4518Z-S 1800*650*690 750 10500 86 115 135
    RM4524Z-S 2400*650*690 1000 14000 119 159 185
    4-5 RM6308Z-S 800*800*850 550 5400 10 DN65 38 50 59
    RM6316Z-S 1600*800*850 1100 10800 90 120 140
    RM6324Z-S 2400*800*850 1650 16200 141 189 220


    Steam Type

    Installation Height
    m
    Model L*W*H
    mm
    Total Motor
    Power
    W(380V)
    Air Volume
    m 3/h
    Air Speed
    m/s
    Inlet/Outlet
    Pipe Diameter
    Steam Pressure 0.1MPa Steam Pressure 0.2MPa Steam Pressure 0.3MPa
    Heating Capacity
    kW
    Heating Capacity
    kW
    Heating Capacity
    kW
    ≤3.2 RM3505Z-Q 500*500*630 170 1600 8 DN32 15 20 23
    RM3509Z-Q 900*500*630 340 3200 30 40 46
    RM3514Z-Q 1350*500*630 510 4800 47 62 71
    RM3518Z-Q 1800*500*630 680 6400 64 85 97
    RM3523Z-Q 2250*500*630 850 8000 81 107 123
    3-4 RM4506Z-Q 600*650*690 250 3500 9 DN40 26 35 40
    RM4512Z-Q 1200*650*690 500 7000 58 77 88
    RM4518Z-Q 1800*650*690 750 10500 90 119 136
    RM4524Z-Q 2400*650*690 1000 14000 122 161 185
    4-5 RM6308Z-Q 800*800*850 550 5400 10 DN50 46 61 70
    RM6316Z-Q 1600*800*850 1100 10800 100 132 151
    RM6324Z-Q 2400*800*850 1650 16200 153 202 232


    Precautions
    1. Engineering matching model, can be customized according to drawing parameters
    2. High energy consumption, not recommended for use unless significant heat supplementation is required

     

     

Product inquiry